Tolerances |
|
BS
4466
Cutting and Bending tolerances |
CP110
schedule dimensions
Deduction for tolerances
|
|
± 25mm
|
Straight lenghts*
including lenghts to be bent |
- 40mm |
Reference
CP 110
Clause
3.11.3.2 |
|
25mm
+ 5 to - 10mm
+ 5 to - 25mm
|
| Bending Dimensions |
≈ 1m |
|
> 1 ≈2m |
|
> 2m |
|
- 10mm
- 15mm
- 20mm |
*
For these shape in particular the effect of a positive
cutting tolerance increasing the actual length of the "free" legs by
up to 25mm should be considered. Bracketted dimensions are run-out dimension and
may be omitted from the final schedule.
For shape codes 60, 81, 72, 73 and 74 internal dimensions, I.D. are assumed. For
shape codes 41, 42, 43 and 49 the formulae for L should not be used for
angles exceeding 45.
|
Specifications |
Minimum
Ultimate Tensile Strength |
| N / mm2
(kfg
/ mm2) |
|
Straight Bars
|
| ASTM
A82 |
|
550 (56.08) |
| ASTM
496 |
|
586 (59.76) |
| ASTM 615 |
G - 40 |
482 (49.15) |
| |
G - 60 |
620 (63.22) |
| BS
4449 |
G - 250 |
250 (25.50) |
| |
G - 460 |
460 (46.90) |
| |
G - 425 |
425 (43.34) |
| BS
4461 |
|
460 (46.90) |
| BS 4482 |
|
485 (49.50) |
| DIN 488 |
|
340 - 500 (34.67 - 50.98) |
| JIS
3112
|
SD 35 |
490 (49.96) |
| |
SD 49
|
559 (57.00) |
|
|